Electrical and electronics measurements miscellaneous
- The number of comparators needed in a parallel conversion type 8-bit A to D convertor is __________
-
View Hint View Answer Discuss in Forum
For parallel conversion type A to D converter, number of comparators required = 2N– 1,
where, N is the number of bits = 28 – 1 = 255Correct Option: A
For parallel conversion type A to D converter, number of comparators required = 2N– 1,
where, N is the number of bits = 28 – 1 = 255
- A 1 mA d’Arsonval movement has resistance of 100 Ω. It is to be converted to a 10 V voltmeter. The value of multiplier resistance is __________Ω
-
View Hint View Answer Discuss in Forum
NA
Correct Option: A
NA
- A zero to 300 V voltmeter has guaranteed accuracy of 1% full scale reading. The voltage measured by the instrument is 83V. The percent limiting error is ___________
-
View Hint View Answer Discuss in Forum
1% accuracy means that a maximum possible error of
300 × 1 = 3 100
may be present in any reading. Since the deflection is 83V, therefore percent limiting error= 3 × 100 = 3.62 83 Correct Option: A
1% accuracy means that a maximum possible error of
300 × 1 = 3 100
may be present in any reading. Since the deflection is 83V, therefore percent limiting error= 3 × 100 = 3.62 83
- A 1 mA ammeter has a resistance of 100Ω. It is to be converted to a 1 A ammeter. The value of shunt resistance is ________Ω
-
View Hint View Answer Discuss in Forum
NA
Correct Option: B
NA
- A milliammeter of resistance 100 Ω is connected in series with a circuit. Its power consumption is 0.1 mW. Supposing it is replaced with a milliammeter of 200Ω resistance the power consumption will be ________mW
-
View Hint View Answer Discuss in Forum
NA
Correct Option: C
NA